Up for sale today we have a Schneider TeSys LRD21 Thermal Overload Relay. It is New in Box. Please look at pictures for best idea of the condition of the item(s).Complementary
network frequency
0...400 Hz
mounting support
Plate, with specific accessories
Rail, with specific accessories
Under contactor
tripping threshold
1.14 +/- 0.06 Ir IEC 60947-4-1
[Ith] conventional free air thermal current
5 A signalling circuit
permissible current
1.5 A 240 V AC-15 signalling circuit
0.1 A 250 V DC-13 signalling circuit
[Ue] rated operational voltage
690 V AC 0...400 Hz
[Uimp] rated impulse withstand voltage
6 kV
phase failure sensitivity
Tripping current 130 % of Ir on two phase, the last one at 0
control type
Red push-button stop
Blue push-button reset
temperature compensation
-4…140 °F (-20…60 °C)
connections - terminals
Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible without cable end
Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end
Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) solid without cable end
Power circuit screw clamp terminals 1 0.00…0.02 in² (1.5…10 mm²) flexible without cable end
Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible with cable end
Power circuit screw clamp terminals 1 0.00…0.01 in² (1…6 mm²) solid without cable end
tightening torque
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals
Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals
width
1.77 in (45 mm)
depth
2.76 in (70 mm)
net weight
0.27 lb(US) (0.124 kg)
Environment
protective treatment
TH IEC 60068
IP degree of protection
IP20 IEC 60529
ambient air temperature for operation
-4…140 °F (-20…60 °C) without derating IEC 60947-4-1
ambient air temperature for storage
-76…158 °F (-60…70 °C)
flame retardance
V1 UL 94
mechanical robustness
Vibrations6 Gn IEC 60068-2-6
Shocks15 Gn for 11 ms IEC 60068-2-7
dielectric strength
6 kV 50 Hz IEC 60255-5
standards
UL 508
IEC 60947-4-1
ATEX D 94/9/CE
IEC 60947-5-1
EN 60947-5-1
CSA C22.2 No 14
EN 60947-4-1
product certifications
GOST
RINA
UL
GL
CCC
BV
LROS (Lloyds register of shipping)
ATEX INERIS
CSA
DNV
range
TeSys
product name
TeSys LRD
product or component type
Differential thermal overload relay
device short name
LRD
relay application
Motor protection
product compatibility
LC1D32
LC1D18
LC1D25
LC1D38
network type
AC
DC
thermal protection adjustment range
12…18 A
[Ui] rated insulation voltage
Power circuit 600 V CSA
Power circuit 600 V UL
Power circuit 690 V IEC 60947-4-1